size
|
|
DN 10 – 250 mm (¼″ – 10″)
|
|
drive
|
pneumatic
|
Equipped with a movable steering wheel
|
|
|
pneumatic
|
Single/double acting with closing spring (NC) or opening spring (NO)
|
|
Valve body material
|
|
Aluminum or stainless steel
|
|
feed mechanism
|
|
Axial push connector
|
|
Standard flange
|
|
ISO-KF,ISO-K
|
|
leakage rate
|
Valve body and valve seat
|
< 1 × 10⁻⁸ mbar l s⁻¹
|
|
pressure range
|
DN 10 – 50
|
1 × 10⁻⁸ mbar to 5 bar (Absolute pressure)
|
|
|
DN 63 – 80
|
1 × 10⁻⁷ mbar 至 4 bar (Absolute pressure)
|
|
|
DN 100 – 160
|
1 × 10⁻⁶ mbar 至 2 bar (绝对压强)
|
|
|
DN 200 – 250
|
1 × 10⁻⁶ mbar to 1.6 bar (Absolute pressure)
|
|
The valve plate can withstand pressure difference
|
Opening direction
|
DN 10 – 50 ≤ 2.0 bar
|
|
|
Close direction
|
DN 63 – 250 ≤ 1.2 barDN 10 – 50
≤ 5.0 barDN 63 – 80 ≤ 4.0 barDN 100 – 160 ≤ 2.0 barDN 200 – 250 ≤ 1.6 bar
|
|
Can withstand pressure difference when opened
|
|
≤ 1 bar
|
|
Valves with manual actuators
|
DN 10 – 80
|
1 one million time
|
|
Number of switches before the first maintenance
|
Valves with pneumatic actuators
|
DN 10 – 80 3 Million times (NC, NO)DN 100
– 160 1 Million times (NC, NO)DN 100 – 160 2 Million times (double-acting)DN 200 – 250 1 Million times (double-acting)
|
|
temperature
|
valve body
|
≤ 150 °C
|
|
|
Manual and Pneumatic Drivers
|
≤ 120 °C
|
|
|
Electromagnetic valve and position indicator
|
DN 10 – 80 ≤ 80 °CDN 100 – 250 ≤
50 °C
|
|
material
|
Aluminum valve body
|
DN 16 – 63 EN AW-6060 (3.3206)、EN AW-6061 (3.3211)
|
|
|
Stainless steel valve body
|
DN 80 – 160 EN AW-6063 (3.3206)DN 10 – 250 EN AW-6082 (3.2315)
|
|
|
valve plate
|
DN 10 – 160 EN AC-42000 / AISI 316L (1.4404)DN 200 – 250 AISI 316L (1.4404, 1.4435) / AISI
304 (1.4301)
|
|
seal
|
Valve cover, valve plate
|
fluororubber (Viton®)
|
|
Installation location
|
|
Any location
|
|
solenoid valve
|
DN 10 – 80
|
24 V DC,2.5 W (Other values can be provided as needed)
|
|
|
DN 100 – 250
|
24 V DC,1.0 W (Other values can be provided upon request)
|
|
Position indicator: Contact rated value
|
voltage
|
DN 10 – 160 5 – 50 V AC/DCDN 200 – 250 ≤ 50 V AC/DC
|
|
|
current
|
DN 10 – 160 5 – 100 mADN 200 – 250 ≤ 1.2 A
|
|
Valve position indication
|
|
Visual (Mechanical)
|