PRODUCT CENTER

GP-21.0 - butterfly valve

When installation space is limited and replacement gate valves are needed, GP-21.0 butterfly valves are the ideal choice. It can provide the same reliable vacuum isolation performance as standard gate valves, while requiring lower installation space.
This series combines the butterfly valve principle with a compact driver design, allowing for smooth installation and operation even in extremely limited space environments.
Product Introduction
Product Parameters
This series combines the butterfly valve principle with a compact driver design, allowing for smooth installation and operation even in extremely limited space environments.
Under any pressure conditions, the GP-21.0 series can maintain stable and reliable operating performance. Its sturdy structural design reduces maintenance workload, making maintenance more convenient and demonstrating excellent comprehensive performance in all aspects.
After extensive practical application verification under harsh process conditions, the GP-21.0 series has become an ideal solution for vacuum pump isolation valves and has been widely used in multiple industries worldwide.

Main features of GP-21.0 butterfly valve

Feature
• Compact design
• Can still operate normally under conditions of pressure difference
• Stable and reliable operation
• Low maintenance volume

Advantage
• Small footprint
• Long normal operating time
• Low operating costs
size DN 63 (2 ½″),DN 100 (4″),DN 160 (6″),DN 250 (10″)
drive pneumatic double-acting
manual With operating lever
Valve body material stainless steel
Screw components rotate
Standard flange DN 63 – 160 ISO-F
DN 250 ISO-F / ISO-K
leakage rate valve body < 1 × 10⁻⁸ mbar l/s
Valve seat manual driver < 5 × 10⁻⁹ mbar l/s
Valve seat pneumatic actuator < 1 × 10⁻⁹ mbar l/s
pressure range Manual drive DN 63 – 100 1 × 10⁻⁸ mbar to 4 bar (Absolute pressure)
DN 160, 250 1 × 10⁻⁸ mbar to 1.3 bar (Absolute pressure)
pneumatic actuator DN 63 – 250 1 × 10⁻⁶ mbar to 1.3 bar (Absolute pressure)
The valve plate can withstand pressure difference Manual drive DN 63 – 100 ≤ 4 bar
DN 160 ≤ 1.3 bar
pneumatic actuator DN 63 – 100 ≤ 1.3 bar
Can withstand pressure difference when opened ≤ 1.3 bar
Number of switches before the first maintenance Manual drive DN 63 – 160 10 one million time
pneumatic actuator DN 63, 250 100 one million time
DN 100, 160 150 one million time
temperature valve body ≤ 150 °C
drive ≤ 80 °C
solenoid valve ≤ 50 °C
position indicator ≤ 80 °C
material Valve body, valve plate, shaft AISI 304 (1.4301)
seal Valve cover, valve plate fluororubber
Installation location Any location
solenoid valve 24 VDC,5.7 W,normally closed (NC)(Other values can be provided as needed)
Position indicator: Contact rated value voltage ≤ 50 VAC / 5 – 30 VDC
current 0.1 A

Tel:

021-33656178

Address:Building 3, Zetian Industrial Park, No. 1121 Wangyuan South Road, Nanqiao Town, Fengxian District, Shanghai

Address:No. 397 Damuqiao Road, Shaxi Town, Taicang City, Jiangsu Province

Address:900W TEMPLE STREET LOS ANGELESS CA 90012

Address:No. 88 Yaowei Mu, Nijiatan Village, Shuanglin Town, Nanxun District, Huzhou City, Zhejiang Province

Copyright © 2026 上海吉派流体控制技术(集团)有限公司
沪ICP备2025189399号-1